中文字幕在线观看国产|天堂无码人妻精品一区|国产精品极品美女自在线|天天躁日日躁狠狠躁视频|国产日韩黑人午夜在线观看|免费一级做a爰片性色毛片|免费久久99精品国产自在现|亚洲日韩欧美在线观看一区二区

AMI System Solution
AMI System Solution


Functions
Administration

? Meter Administration
? Concentrator Administration
? Monitoring of System Components Replacement History
? Monitoring of Command and Parameter History of System Components
? Defining of Roles and Users/User Groups
? Access Control to System Components and AMR Centre
? Administration of reporting functions of AMI Centre
? Regular Automatic Backup of All Data At the Desired Time

Data Reading/Collection and Archiving

? Reading of Individual Concentrator/meter

? Reading of the Group of Concentrators/Meters

? Automated Reading According to the Sequence

? Reading On Request

? Periodical Reading on Request

? Special Reading on Request

? Data collected automatically according to the sequence set in advance include the following

  ? Daily Register Values

  ? Meter States

  ? Electricity Quality Log

  ? Event Log

  ? Load Profile

  ? Hourly Register Values

  ? State of Monthly Accounting Registers

  ? Time and Date


? Data collected from the meter on request including:

  ? Effective Voltage Values Per Phases At the Moment of Reading

  ? Effective Current Values Per Phases At the Moment of Reading

  ? Current Power–(Load Power At the Moment of Reading)

  ? Tariff Programmer

  ? Integration Period for 15-Minute Maximum Power

  ? Consumption Management Parameters

  ? Parameters for Voltage Thresholds Within Electricity Quality Log

  ? Parameters or Time Intervals of Profiles

  ? Parameters for Registers Within Profiles

  ? Parameters Related to the Presentation On Meter Display

  ? Archive States of Accounting Registers

  ? Current State of Bi-stabile Switch

  ? Meter Software Version

  ? Factory Number and Type of Meter


? Data read according to the sequence from the concentrator including:

  ? Statistics of Communication / Emergency and Regular Reports


? Data read from the concentrator upon the request including:

  ? Concentrator Data Archive

  ? Reading Programmes/Sequences

  ? Management/Parameterisation Programmes/Sequences

  ? Programmes/Sequences Execution Priorities

  ? Communication Routes

  ? Concentrator Response Time and Frequency Parameters

  ? Communication Parameters of the Concentrator

  ? Current Date and Time

  ? Other Concentrator Parameters

  ? Concentrator Software Version

  ? Records on Concentrator Parameter Changes and Adjustments

Reporting functions

? Reports with Analysis of Statuses and Alarms

? Reports on Electricity Quality

? Reports Related to Parameterization and Management

? Communication Reports

? Control Reports

? Reports Generated by the Concentrator

Data and Information Exchange with Other Information Systems and Subsystems of Electric Utility Robust protocol library for various types of DCUs and electronic energy meters, DLMS/COSEM, IEC61870-5-102 compliant